ALIGNMENT TROUBLESHOOTING
32 ANSIFAM IOM - 5/08
Table 1
Cold Setting of Parallel Vertical Alignment
Pumpage
Temperature
Set Driver Shaft, Inches (mm)
3196 CV 3196 HT 3196 LF 3196 NM 3196 3198 3796
50° F (10° C) .002 (.05) low .002 (.05) low 0.000 .002 (.05) low .002 (.05) low .002 (.05) low .002 (.05) low
150° F F (65° C) .001 (.03) high .001(.03) high 0.000 .001(.03) high .001(.03) high .001(.03) high .001(.03) high
250° F (120° C) .005 (.12) high .005 (.12) high 0.000 .005 (.12) high .005 (.12) high .005 (.12) high .005 (.12) high
350° F (175° C) .009 (.23) high .009 (.23) high 0.000 .009 (.23) high N/A .009 (.23) high .009 (.23) high
450° F (218° C) .013 (.33) high .013 (.33) high 0.000 .013 (.33) high N/A N/A .013 (.33) high
550° F (228° C) .017 (.43) high .017 (.43) high 0.000 .017 (.43) high N/A N/A .017 (.43) high
650° F (343° C) .021 (.53) high .021 (.53) high 0.000 .021 (.53) high N/A N/A N/A
700° F (371° C) .023 (.58) high .023 (.58) high 0.000 .023 (.58) high N/A N/A N/A
NOTE: For the HT 3196, the cold setting of parallel vertical is 0.0 for all pumpage temperatures due to centerline mounting.
Table 2
Problem Problem Cause Remedy
Cannot obtain horizontal (Side-to-Side)
alignment, angular or parallel
Driver feet bolt bound.
Loosen pump hold down bolts and slide pump
and driver until horizontal alignment is
achieved.
Baseplate not leveled properly, probably
twisted.
Determine which corner(s) of the baseplate are
high or low and remove or add shims at the
appropriate corner(s) and realign.