7.4.3.2.6. Dismantling of hydraulic unit
Dismantle bearings in accordance with 7.4.3.2.3 a) or b)
Dismantle shaft seal in accordance with 7.4.3.2.4 a) or b)
Dismantle balancing device in accordance with 7.4.3.2.5
- Remove key 940.2
- Release nuts 920.1
- Remove tie bolts 905
- Support stage casing 108.1
- Remove delivery casing 107
- Remove, from stage to stage, impeller 230, key 940.1,
stage casing 180.1 with diffuser 171.1, in that order
7.5 Work after disassembly
- Clean all parts.
- Clean the clearances and sealing surfaces.
The following pump components, if existing, must be
checked:
Mechanical seal
If the running faces are damaged or worn, replace the
mechanical seal.
Clearances
The diameter difference between impeller clearance area
and casing or cover clearance area of a new pump is
between 0.3 and 0.6 mm, depending on size and material.
In the case of excessive wear in the clearance area, wear
rings must be installed.
Shaft
Carry out a concentricity check.
7.6 Assembly
CAUTION
The assembly work must be based on good
engineering practice.
- Use no force.
- Heavy parts must be supported during assembly.
- Before assembly, apply a layer of an appropriate
erection substance on the fitting points. Observe
instructions with regard to cleanliness and safety.
- The properties of new pump components must not be
changed without our head office's consent.
- All parts must be clean and free from chips or dust.
- The unit may be re-assembled in the reverse manner to
disassembling.
- Observe the tightening torques specified.
- Quick-sticking glues are not permitted.
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 43 44